Wema
Wema -ryhmän tuotteet

- Material: stainless steel
- SAE 5-hole pitch
- Flange pitch Ø 54 mm
- Resistance value 0 - 190 (OHM)
- Works for all meters that operate between 0 and 190 (OHM) (start value-end value).

Compatible with yellow CAN-SB tanks. Other tanks require a flange for the lid, e.g. 9514700150, 9514700140, 9514700147 or 9514700145. Installation should be done so that the sensor can be lifted out of the tank for maintenance.
- Sensor for measuring the content of a septic tank
- Material stainless steel
- Sensor mounting with 1 1/4” BSP thread
- Lengths: 100, 205, 305, 410, 510 and 750mm.
- Resistance value 240-30 ?

- Sensor for Wema fuel and water tank gauges
- With 1 1/4 BSP thread
- For meters that operate between 0-190 ohms
- Stainless

Oil pressure sensor with grounding and alarm 5bar and 1/8" NPTF thread. The sensor is suitable for most engines that do not have an engine-specific grounding.
Specifications:
- Measuring range: 0–5bar
- Thread: 1/8" NPTF
- Suitable for motors without grounding
- M4 bolt for signal, ground and alarm connection
- Alarm activated at 0.8bar ±0.2bar
- Oil pressure sensor
- Wema

- Pendulum sensor
- 0-180 ohms
- For tank depth: 15-60cm
- Note: Not suitable for use in water tanks.

Fuel gauge for boat on black background. Installation size general 52mm.
- Fuel gauge for S3/S5 sensors
- 0 - 190 ohms
- Installation Ø 52 mm
- Installation depth 62 mm
- Overall diameter 62 mm
- Standard red and yellow lighting
- Operating voltage 12/24 V
- Black base and black frame.

Oil pressure sensor WEMA
Suitable for all common brands, such as VDO, Wema, Uflex, Faria etc. Connects to oil pressure gauge. 1/8" NPTF thread.
Measuring range : 0–5 bar
Thread : 1/8" NPTF
Compatibility : Fits most motors where grounding is through the motor
Connections : M4 screws for signal, ground and alarm connections
Alarm limit : 0.8 bar ± 0.2 bar
- Oil pressure sensor
- Wema

Tachometer with 0-4000 RPM display range, and LCD hour meter. Connects to the W terminal of the charger. Installation Ø 85 mm, installation depth 55 mm. Red and yellow lighting as standard. Operating voltage 12 or 24 V. Black base / black frame.
- Diameter: 85mm
- Installation depth: 55mm
- Red and yellow lighting

Tachometer with 0-8000 RPM display range and LCD hour meter. Connects to the W terminal of the charger. Installation Ø 85 mm, installation depth 55 mm Standard red and yellow lighting. Operating voltage 12 or 24 V. White base, stainless steel frame.
- Tachometer 0-8000 RPM
- Installation Ø 85mm
- Operating voltage 12V or 24V

A NMEA2000 voltage isolator is a useful accessory for the proper installation of a NMEA2000 network, as it separates the different power sources that can power the network. For example, compatible motors can power the NMEA2000 network, and the voltage isolator ensures that the electricity supplied to the motors and the main power source of the network remains separate. Without a voltage isolator, there is a risk that the starter batteries will be drained by the NMEA2000 network, or that the network will stop working when the engine is turned off.
Weman's NMEA2000 voltage isolator is installed between T-connectors and isolates one side of the backbone network from the other. The connector is waterproof (IP67 rated) and compatible with all manufacturers' NMEA2000 connectors, cables and sensors with plug & play installation.
- Voltage isolator
- NMEA2000
- Waterproof IP67

Tachometer with 0-4000 RPM display range and LCD hour meter. Connects to the W terminal of the charger. Installation Ø 85mm, installation depth 55mm Standard red and yellow lighting. Operating voltage 12 or 24 V. White base, stainless steel frame.
- Tachometer 0-4000 RPM
- Installation Ø 85mm
- Operating voltage 12 or 24 V

NMEA2000 network starter kit. Includes branch/trunk cables, T-connectors, termination resistors and power cable with fuse
Package contents
- 1 x 2m trunk cable/branch cable
- 1 x 6m trunk cable/branch cable
- 1 x 2m power cable with 3A fuse
- 2 x T-connector
- 1 x male termination resistor
- 1 x female termination resistor
- NMEA2000 Basic Starter Kit
- 1 x 2m trunk cable/branch cable
- 1 x 6m trunk cable/branch cable
- 1 x 2m power cable with 3A fuse
- 2 x T-connector
- 1 x male termination resistor
- 1 x female termination resistor

Wema uses NMEA2000 Micro connectors in cables and connectors,
- NMEA2000 Drop Cable
- Length: 6m
- The cable features 18 AWG power conductors, minimizing the risk of voltage drop and providing improved reliability for the NMEA 2000 network

NMEA2000 extension connector, male-male
In a NMEA2000 network, there can sometimes be a problem where two devices or cables to be connected have identical connectors. This problem can be easily solved by using an extension connector.The connector is waterproof (IP67) and compatible with NMEA2000 connectors, cables and sensors from all manufacturers.
- Male-male
- NMEA2000
- Waterproof IP67

NMEA 2000® certified T-connector
T-connectors are needed to add devices and build a NMEA2000 network. It is installed on the trunk cable and uses the other end of the T-connector for a drop cable. Plug and play with other manufacturers' NMEA2000 T-connectors, cables and sensors.
- T-connector for NMEA2000 network
- NMEA2000 certified
- Compatible with NMEA2000 products from other manufacturers
- IP68 waterproof

NMEA2000 branch cable
- NMEA2000 Drop Cable
- Length: 4m
- The cable features 18 AWG power conductors, minimizing the risk of voltage drop and providing improved reliability for the NMEA 2000 network